Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Arq Bras Cardiol ; 117(5): 1018-1027, 2021 11.
Artigo em Inglês, Português | MEDLINE | ID: mdl-34817012

RESUMO

BACKGROUND: C-reactive protein (CRP) is an inflammation biomarker that can be a predictor of adverse events in cardiovascular procedures. Its use in the assessment of long-term prognosis of transcatheter aortic valve implantation (TAVI) is still incipient. OBJECTIVE: To evaluate CRP as a prognostic marker in the first year after TAVI in aortic stenosis (AoS). METHODS: CRP was assessed on the first postoperative week in a retrospective cohort of patients with AoS. Pre- and post- CRP levels were correlated with mortality, and predictors of 1-year mortality were investigated. Multivariate Cox regression was performed to identify independent factors of 1-year mortality. RESULTS: This study evaluated 130 patients who underwent TAVI, with median age of 83 years, and 49% of women. High pre-TAVI CRP (> 0.5 mg/dL) was observed in 34.5% of the cases. Peak CRP was 7.0 (5.3-12.1) mg/dL no quarto dia. The rate of 1-year mortality was 14.5% (n = 19), being greater in the groups with high pre-TAVI CRP (68.8% vs 29.1%; p = 0,004) and with peak CRP ≥ 10.0 mg/dL (64.7% vs 30.8%; p = 0,009). Independent predictors of mortality were acute renal failure (ARF) (hazard ratio [HR] = 7.43; 95% confidence interval [95%CI], 2.1-24.7; p = 0,001), high pre-TAVI CRP (HR 4.15; 95%CI, 1.3-12.9; p = 0.01), and large blood transfusion [HR 4,68; 1,3-16,7; p = 0.02]. CONCLUSIONS: High pre-TAVI CRP showed to be an independent predictor of 1-year mortality, as well as the presence of ARF and large blood transfusions.


FUNDAMENTO: A proteína C-reativa (PCR) é um biomarcador de inflamação preditor de eventos adversos em procedimentos cardiovasculares. Na avaliação do implante da válvula aórtica transcateter (transcatheter aortic valve implantation, TAVI) em relação ao prognóstico de longo prazo ainda é incipiente. OBJETIVO: Avaliar a PCR como marcador prognóstico no primeiro ano pós-TAVI na estenose aórtica (EAo). MÉTODOS: A PCR foi avaliada na primeira semana do peroperatório numa coorte de casos retrospectiva com EAo. Correlacionou-se a PCR pré- e pós-TAVI com a mortalidade e foram pesquisados fatores preditores de mortalidade em 1 ano. Realizada regressão de Cox multivariada para identificar os preditores independentes de óbito em 1 ano. RESULTADOS: Estudados 130 pacientes submetidos a TAVI, com mediana de idade de 83 anos, sendo 49% deles do sexo feminino. A PCR pré-TAVI elevada (> 0,5 mg/dL) ocorreu em 34,5% dos casos. O pico de PCR foi 7,0 (5,3-12,1) mg/dL no quarto dia. A mortalidade em 1 ano foi 14,5% (n = 19), sendo maior nos grupos com PCR pré-TAVI elevada (68,8% vs 29,1%; p = 0,004) e pico de PCR ≥ 10,0 mg/dL (64,7% vs 30,8%; p = 0,009). Os fatores preditores independentes de mortalidade foram insuficiência renal aguda (IRA) [razão de risco (RR) = 7,43; intervalo de confiança de 95% (IC95%), 2,1-24,7; p = 0,001], PCR pré-TAVI elevada [RR = 4,15; IC95%, 1,3-12,9; p=0,01] e hemotransfusão volumosa [HR = 4,68; 1,3-16,7; p = 0,02]. CONCLUSÕES: A PCR pré-TAVI elevada mostrou-se fator preditor independente de mortalidade no primeiro ano, assim como a ocorrência de IRA e hemotransfusões volumosas.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Proteína C-Reativa/análise , Feminino , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Arq. bras. cardiol ; 117(5): 1018-1027, nov. 2021. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1350022

RESUMO

Resumo Fundamento: A proteína C-reativa (PCR) é um biomarcador de inflamação preditor de eventos adversos em procedimentos cardiovasculares. Na avaliação do implante da válvula aórtica transcateter (transcatheter aortic valve implantation, TAVI) em relação ao prognóstico de longo prazo ainda é incipiente. Objetivo: Avaliar a PCR como marcador prognóstico no primeiro ano pós-TAVI na estenose aórtica (EAo). Métodos: A PCR foi avaliada na primeira semana do peroperatório numa coorte de casos retrospectiva com EAo. Correlacionou-se a PCR pré- e pós-TAVI com a mortalidade e foram pesquisados fatores preditores de mortalidade em 1 ano. Realizada regressão de Cox multivariada para identificar os preditores independentes de óbito em 1 ano. Resultados: Estudados 130 pacientes submetidos a TAVI, com mediana de idade de 83 anos, sendo 49% deles do sexo feminino. A PCR pré-TAVI elevada (> 0,5 mg/dL) ocorreu em 34,5% dos casos. O pico de PCR foi 7,0 (5,3-12,1) mg/dL no quarto dia. A mortalidade em 1 ano foi 14,5% (n = 19), sendo maior nos grupos com PCR pré-TAVI elevada (68,8% vs 29,1%; p = 0,004) e pico de PCR ≥ 10,0 mg/dL (64,7% vs 30,8%; p = 0,009). Os fatores preditores independentes de mortalidade foram insuficiência renal aguda (IRA) [razão de risco (RR) = 7,43; intervalo de confiança de 95% (IC95%), 2,1-24,7; p = 0,001], PCR pré-TAVI elevada [RR = 4,15; IC95%, 1,3-12,9; p=0,01] e hemotransfusão volumosa [HR = 4,68; 1,3-16,7; p = 0,02]. Conclusões: A PCR pré-TAVI elevada mostrou-se fator preditor independente de mortalidade no primeiro ano, assim como a ocorrência de IRA e hemotransfusões volumosas.


Abstract Background: C-reactive protein (CRP) is an inflammation biomarker that can be a predictor of adverse events in cardiovascular procedures. Its use in the assessment of long-term prognosis of transcatheter aortic valve implantation (TAVI) is still incipient. Objective: To evaluate CRP as a prognostic marker in the first year after TAVI in aortic stenosis (AoS). Methods: CRP was assessed on the first postoperative week in a retrospective cohort of patients with AoS. Pre- and post- CRP levels were correlated with mortality, and predictors of 1-year mortality were investigated. Multivariate Cox regression was performed to identify independent factors of 1-year mortality. Results: This study evaluated 130 patients who underwent TAVI, with median age of 83 years, and 49% of women. High pre-TAVI CRP (> 0.5 mg/dL) was observed in 34.5% of the cases. Peak CRP was 7.0 (5.3-12.1) mg/dL no quarto dia. The rate of 1-year mortality was 14.5% (n = 19), being greater in the groups with high pre-TAVI CRP (68.8% vs 29.1%; p = 0,004) and with peak CRP ≥ 10.0 mg/dL (64.7% vs 30.8%; p = 0,009). Independent predictors of mortality were acute renal failure (ARF) (hazard ratio [HR] = 7.43; 95% confidence interval [95%CI], 2.1-24.7; p = 0,001), high pre-TAVI CRP (HR 4.15; 95%CI, 1.3-12.9; p = 0.01), and large blood transfusion [HR 4,68; 1,3-16,7; p = 0.02]. Conclusions: High pre-TAVI CRP showed to be an independent predictor of 1-year mortality, as well as the presence of ARF and large blood transfusions.


Assuntos
Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/metabolismo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Prognóstico , Proteína C-Reativa/análise , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
3.
Arq. bras. cardiol ; 106(6): 519-527, tab, graf
Artigo em Inglês | LILACS | ID: lil-787321

RESUMO

Abstract Background: Transcatheter aortic valve implantation has become an option for high-surgical-risk patients with aortic valve disease. Objective: To evaluate the in-hospital and one-year follow-up outcomes of transcatheter aortic valve implantation. Methods: Prospective cohort study of transcatheter aortic valve implantation cases from July 2009 to February 2015. Analysis of clinical and procedural variables, correlating them with in-hospital and one-year mortality. Results: A total of 136 patients with a mean age of 83 years (80-87) underwent heart valve implantation; of these, 49% were women, 131 (96.3%) had aortic stenosis, one (0.7%) had aortic regurgitation and four (2.9%) had prosthetic valve dysfunction. NYHA functional class was III or IV in 129 cases (94.8%). The baseline orifice area was 0.67 ± 0.17 cm2 and the mean left ventricular-aortic pressure gradient was 47.3±18.2 mmHg, with an STS score of 9.3% (4.8%-22.3%). The prostheses implanted were self-expanding in 97% of cases. Perioperative mortality was 1.5%; 30-day mortality, 5.9%; in-hospital mortality, 8.1%; and one-year mortality, 15.5%. Blood transfusion (relative risk of 54; p = 0.0003) and pulmonary arterial hypertension (relative risk of 5.3; p = 0.036) were predictive of in-hospital mortality. Peak C-reactive protein (relative risk of 1.8; p = 0.013) and blood transfusion (relative risk of 8.3; p = 0.0009) were predictive of 1-year mortality. At 30 days, 97% of patients were in NYHA functional class I/II; at one year, this figure reached 96%. Conclusion: Transcatheter aortic valve implantation was performed with a high success rate and low mortality. Blood transfusion was associated with higher in-hospital and one-year mortality. Peak C-reactive protein was associated with one-year mortality.


Resumo Fundamento: O implante de válvula aórtica por cateter tornou-se uma opção para pacientes com doença valvar aórtica de elevado risco cirúrgico. Objetivo: Avaliar os resultados dos seguimentos intra-hospitalar e de até 1 ano do implante de válvula aórtica por cateter. Métodos: Estudo de coorte prospectiva de casos de implante de válvula aórtica por cateter entre julho de 2009 e fevereiro de 2015. Análise de variáveis clínicas e do procedimento, correlacionando com mortalidade intra-hospitalar e de 1 ano. Resultados: Foram submetidos ao implante 136 pacientes, com média de idade de 83 (80-87) anos, sendo 49% mulheres, 131 (96,3%) deles com estenose aórtica, um (0,7%) com insuficiência aórtica e quatro (2,9%) com disfunção de prótese. A classe funcional da NYHA foi III ou IV em 129 (94,8%) casos. A área valvar inicial foi 0,67 ± 0,17 cm2 e o gradiente ventrículo esquerdo-aorta médio de 47,3 ± 18,2 mmHg, com STS de 9,3% (4,8%-22,3%). As próteses implantadas eram autoexpansíveis em 97% dos casos. A mortalidade peroperatória em 1,5% dos casos; em 30 dias em 5,9%; intra-hospitalar em 8,1%; e após 1 ano em 15,5% dos casos. A hemotransfusão (risco relativo de 54; p = 0,0003) e a hipertensão arterial pulmonar (risco relativo de 5,3; p = 0,036) foram preditoras de mortalidade hospitalar; e a proteína C-reativa pico (risco relativo de 1,8; p = 0,013) e a hemotransfusão (risco relativo de 8,3; p = 0,0009) de mortalidade em 1 ano. Aos 30 dias, 97% dos pacientes estavam em classe NYHA I/II e, em 1 ano, o número chegou a 96%. Conclusão: O implante de válvula aórtica por cateter foi realizado com alto índice de sucesso e baixa mortalidade. A hemotransfusão associou-se com maior mortalidade hospitalar e de 1 ano. Proteína C-reativa pico se associou com a mortalidade de 1 ano.


Assuntos
Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Mortalidade Hospitalar , Substituição da Valva Aórtica Transcateter/mortalidade , Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/epidemiologia , Complicações Pós-Operatórias/mortalidade , Fatores de Tempo , Brasil/epidemiologia , Métodos Epidemiológicos
4.
Arq Bras Cardiol ; 106(6): 519-27, 2016 Jun.
Artigo em Inglês, Português | MEDLINE | ID: mdl-27192383

RESUMO

BACKGROUND: Transcatheter aortic valve implantation has become an option for high-surgical-risk patients with aortic valve disease. OBJECTIVE: To evaluate the in-hospital and one-year follow-up outcomes of transcatheter aortic valve implantation. METHODS: Prospective cohort study of transcatheter aortic valve implantation cases from July 2009 to February 2015. Analysis of clinical and procedural variables, correlating them with in-hospital and one-year mortality. RESULTS: A total of 136 patients with a mean age of 83 years (80-87) underwent heart valve implantation; of these, 49% were women, 131 (96.3%) had aortic stenosis, one (0.7%) had aortic regurgitation and four (2.9%) had prosthetic valve dysfunction. NYHA functional class was III or IV in 129 cases (94.8%). The baseline orifice area was 0.67 ± 0.17 cm2 and the mean left ventricular-aortic pressure gradient was 47.3±18.2 mmHg, with an STS score of 9.3% (4.8%-22.3%). The prostheses implanted were self-expanding in 97% of cases. Perioperative mortality was 1.5%; 30-day mortality, 5.9%; in-hospital mortality, 8.1%; and one-year mortality, 15.5%. Blood transfusion (relative risk of 54; p = 0.0003) and pulmonary arterial hypertension (relative risk of 5.3; p = 0.036) were predictive of in-hospital mortality. Peak C-reactive protein (relative risk of 1.8; p = 0.013) and blood transfusion (relative risk of 8.3; p = 0.0009) were predictive of 1-year mortality. At 30 days, 97% of patients were in NYHA functional class I/II; at one year, this figure reached 96%. CONCLUSION: Transcatheter aortic valve implantation was performed with a high success rate and low mortality. Blood transfusion was associated with higher in-hospital and one-year mortality. Peak C-reactive protein was associated with one-year mortality.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Mortalidade Hospitalar , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/epidemiologia , Brasil/epidemiologia , Métodos Epidemiológicos , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...